Sterile Surgical Gloves
Anatomical curve, micro-rough grip for surgical precision.
Price on Request
In StockDirect wholesale & retail pricing handled instantly on WhatsApp • 50 pairs/box.
Key Clinical Benefits
- Pre-curved anatomical fingers prevent hand fatigue during long surgeries
- Micro-rough finish for confident wet and dry instrument grip
- Individually packed in sterile peel-open wallets
- Extra-long beaded cuff (280mm+) for secure gown grip
Product Description
Engineered specifically for surgical teams, our Sterile Surgical Gloves provide an impenetrable biological barrier combined with supreme tactile sensitivity. Featuring pre-curved fingers that match natural hand anatomy, they eliminate palm tension and hand fatigue during lengthy surgical procedures. Individually packed in sealed sterile peel-open pouches with clear Left/Right demarcation.
Technical Specifications
| Material | Natural Rubber Latex |
|---|---|
| Sterilization | Ethylene Oxide (EO) / Gamma Irradiation |
| AQL | 1.0 / 1.5 Surgical Grade |
| Length | ≥ 280 mm |
| Cuff | Reinforced Beaded |
| Shape | Anatomical (Left / Right) |
| Packaging | 1 Pair/Pouch, 50 Pairs/Box |
| Sizes | 6.0, 6.5, 7.0, 7.5 |
Comprehensive Technical Matrix
Verified clinical laboratory values and ASTM / EN compliance parameters.
| Size Designation | Palm Width (mm) | Minimum Length (mm) |
|---|---|---|
| 6.0 | 77 ± 5 mm | ≥ 280 mm |
| 6.5 | 83 ± 5 mm | ≥ 280 mm |
| 7.0 | 89 ± 5 mm | ≥ 285 mm |
| 7.5 | 95 ± 5 mm | ≥ 285 mm |
* Measured across the center of the palm above the base of the thumb in accordance with EN 455-2 & ASTM D6319/D3578.
Master Shipper & Packaging Logistics
Standardized packaging metrics for hospital central supply, pharmacies, and freight logistics.
Standard clinical dispenser box with perforated top-pull opening and moisture-resistant internal seal.
5-ply heavy duty corrugated cardboard carton engineered for multi-tier stacking and long-distance freight.
Certifications & Standards
ISO 13485:2016
Medical Device Quality Management System governing raw material purity, cleanroom production, and lot traceability.
EN 455 (Parts 1–4)
European standard for medical gloves: Part 1 (AQL 1.5 pinholes), Part 2 (Force at break ≥ 6N), Part 3 (Biological safety), Part 4 (Shelf life & aging).
CE Marking (MDR 2017/745)
Conformity marking for medical devices and sterile barrier products under European MDR regulations.
ASTM D3578
Standard specification for Natural Rubber Latex Gloves: tensile strength ≥ 18 MPa unaged / ≥ 14 MPa aged, elongation ≥ 650%, and low-protein limits.